Building Permits in ZIP 90744
Los Angeles, CA — 76 permits filed recently
76 permits
Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 25 Squares. Class A roof covering is required within Very High Fire Hazard Severi...
Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 8 Squares. Class A roof covering is required within Very High Fire Hazard Severit...
1 bathroom(s).Bathroom remodel for residential buildings (no structural changes).Kitchen remodel for residential buildings (no structural changes).
Supplemental work to 20016-20000-30708: revise floor plan layout, enclose (e) 26sf porch for office extension, revise ada ramp access, and correct structural inventory [see comments]_ per engineered p...
Shoring permit for excavation work under grading permit #25030-10000-08809
Install window signs: e04: (1) 9'' x 6 '-3/4" =5.06sf vinyl "wells fargo, hello" ne05 (6) 0'-3" x 2'-7 9/16" =.66sf vinyl "wells fargo" @3'-9" from grade
INSTALL (2) 2' X 21'-8 3/8" =42.75SF ILLUM CHANNEL LETTER WALL SIGNS "WELLS FARGO" E02: at 19 ft from grade E03: at 17 ft from grade
Install (1) 2 3/4" x 28 15/16" =.55 sf non-illum awning signs ( e07: "wells fargo") @ 9' from grade
Eplan. extra mile adding faux wood panels to the front elevation above the window.
Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over new solid sheathing 40 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zo...
NEW CAST IN PLACE REINFORCED CONCRETE ARCH PEDESTRIAN BRIDGE WITH POST TENSIONED CONCRETE DECK. Construction shall not commence without a CALOSHA permit
5--Window and 2--door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council (NFRC), is required for doors and windows rep...
Concrete reinforced retaining wall supported on precast prestressed concrete piles for a future park and Avalon pedestrian bridge project. Design heights for retaining wall are 14', 17', and 20' total...
Re-roof with Class A or B material weighing less than 6 pounds per sq. ft. over EXISTING solid sheathing __50____Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone (...
Install radiant barrier and/or insulation in attic for residential buildings.
Supplemental permit to 26016 - 90000 - 00859 for change in address from 926 N Gulf Ave to 924 N Gulf Ave..