New Construction - FOR THE INSTALLATION OF AN AUTOMATIC FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13D THROUGHOUT THREE STORY BUILDING TO INCLUDE 1-INCH COMBINED WATER SERVICE LINE AS PER APPROVE...
Alterations - REPAIR/REPLACE CT, FAI & MD.
Addition and/or Alteration - Interior fit-out of a proposed office space within an existing warehouse, including the installation of lighting, exit signs, emergency lighting, lighting controls, and re...
Addition and/or Alteration - Install 60A panel ,all lighting ,receptacles ,floor receptacles . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. **FIRE ALARM WILL BE UNDER SEPARATE PERMI...
Addition and/or Alteration - FOR SITEWORK AND INSTALLATION OF PLAYGROUND EQUIPMENT PER APPROVED PLAN.
Sign - INSTALLATION OF ONE (1) ILLUMINATED DOUBLE-SIDED FREESTANDING SIGN ON THE EXISTING FOOTER AND STEEL SUPPORT. SIZE AND LOCATION AS SHOWN ON THE PLAN. SIGNS ACCESSORY TO A RETAIL SALES OF FOOD, B...
Addition and/or Alterations - FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FO...
Alterations - REPAIR/REPLACE CT, FAI & 10ft of MD.
EZ Roof Covering Replacement - EZ PERMIT RE-ROOFING- For the Installation of New Roof Coverings on Existing Roofs as per attached standard. Deviations from these standards require submission of constr...
New Construction or Additions - Install water lines to fixtures, Install drain lines to fixtures, Install 35 toilets, Install 35 tubs/showers, Install 35 Lavatories, install 22 kitchen sinks, 22 Laund...
Addition and/or Alteration - Installation of two panels one 200 amp the other 400 amp Interior wiring of lights receptacles and HVAC termination. Per plans NEC 2017 Installation of Fire alarm. Per pla...
General Earth Disturbance ONLY - FOR THE GENERAL EARTH DISTURBANCE ASSOCIATED WITH TANK REPAIRS. SIZE AND LOCATION AS SHOWN IN THE APPLICATION / PLANS.
Alterations - Install 9 hub drains, 15 floor sinks, 3 floor drains, 1 grease interceptor, 1 three compartment sink, 1 mop sink, 5 kitchen sinks, 1 hot water heater, 1 lavatory, 1 water closet, i hose...
Alterations - REPLACE 5 FIXTURES 1 full bath, 1 urinal, injection pump.
Signs (Accessory / Non-Accessory) - FOR THE ERECTION OF ONE STATICALLY ILLUMINATED DOUBLE FACED ACCESSORY FREESTANDING SIGN. SIZE AND LOCATION AS SHOWN IN PLANS.
Alterations - REPAIR/REPLACE CT, FAI & PARTIAL MD.
Addition and/or Alteration - Install new light fixtures, HVAC power wiring, new 208/120V 600A 3Ph 4W MDP, new 100KVA NEMA-1 208V:240V/120 IPH XFMR as per 2017 NEC. Primary service by PECO. We are prov...
EZ Interior Non-Load-Bearing Wall Demo. - For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards,...
Addition and/or Alteration - Full rewire, New 100 amp service and panel/smokes per NEC CODE 24 lights through/new outlets, switches
Addition and/or Alteration - FOR CHANGE OF USE (NO CHANGE OF OCCUPANCY CLASSIFICATION) AND LEVEL II ALTERATIONS TO INCLUDE EXTERIOR WALL OPENINGS, PARTITIONS, DOORS, FIXTURES, FINISHES AS PER APPROVED...