Renovation Permits in Chicago, Illinois
855 renovation permits filed recently
855 permits
Tuckpointing and unit masonry repair / replacement: 20 sq. ft., lintel qty. 0, max. length 0. location: masonry repairs replace about 400 defective bricks.
Spr 2019 cbc interior and exterior alterations and elevator shaft addition to convert existing 3 story convent to educational learning center for people with autism (occ e1. con iia sprinkled) includi...
Spr 2019 cbrc: interior alterations of existing single story building to remove non-load bearing cmu partition and infill existing internal depressed loading dock with new slab (occupancy group f-1; t...
Tuckpointing and unit masonry repair / replacement: 980 sq. ft., lintel qty. 0, max. length 0. location: front facade.
Tuckpointing and unit masonry repair / replacement: 292 sq. ft., lintel qty. 0, max. length 0. location: front elevation.
Tuckpointing and unit masonry repair / replacement: 10 sq. ft., lintel qty. 0, max. length 0. location: rear house.
Tuckpointing and unit masonry repair / replacement: 500 sq. ft., lintel qty. 1, max. length 3. parapet rebuilding: 75 sq. ft. location: exterior masonry repairs to address violations..
Tuckpointing and unit masonry repair / replacement: 500 sq. ft., lintel qty. 0, max. length 0. location: tuckpointing front elevation.
Tuckpointing and unit masonry repair / replacement: 200 sq. ft., lintel qty. 0, max. length 0. location: building exterior.
Renovation existing building after fire, 10'x12' rear frame addition (conditional permit subject to field inspections)
Concrete masonry repair / replacemnt: 3000sq. ft., excavation = no. location: floors 6,7,&8 of existing parking garage.
Self-cert 2019 cbc: interior alterations of existing offices on floors 9, 10, 11 & 12. area of work 37,464 sq ft. no change to existing group b, business occupancy or existing construction type i-a.
Spr 2019 cbc interior renovations to the 2 story, 2 dwelling unit type va frame building and replace the enclosed rear wood stairs, as per architectural plans. r5 occupancy type.
Tuckpointing and unit masonry repair / replacement: 800 sq. ft., lintel qty. 0, max. length 0. parapet rebuilding: 300 sq. ft. location: front and side of building.
Tuckpointing and unit masonry repair / replacement: 800 sq. ft., lintel qty. 0, max. length 0. location: building exterior.
Spr 2019 cbrc: exterior repairs to damaged column; tuck point existing brick on masonry elevations; as required; address building citations.(occupancy: m, construction type iia)
Tuckpointing and unit masonry repair / replacement: 1000 sq. ft., lintel qty. 0, max. length 0. location: all elevations.
Spr 2019 cbrc: interor alterations to existing 3 story single family home to include renovation of existing kitchen and rear entry, replacement of 7 exterior door and windows within existing openings...
Self-cert 2019 cbrc: alteration of interior office suite on floor 4 in an existing 12 story building (occupancy group b / type 1a construction)
Self-cert 2019 cbrc: revision to permit 101064417 to include the replacement of an existing tin ceiling on the 1st floor business unit and replace with a new 5/8" gypsum board ceiling. the original pe...