New Construction Permit — 2201 E TIOGA ST
New Construction
Not listed
Mk Fire Protection & Supply, Llc
Sepviva Lofts Llc
Philadelphia County
Work Description
New Construction - FOR THE INSTALLATION OF AUTOMATIC WET AND DRY SPRINKLER SYSTEMS IN ACCORDANCE WITH NFPA 13 TO INCLUDE A FOUR (4) INCH FIRE SERVICE LINE AND A FOUR (4) INCH BACKFLOW PREVENTER. CLASS 1 MANUAL WET STANDPIPES TO BE INSTALLED IN EXIT STAIRWAY ENCLOSURES IN ACCORDANCE WITH NFPA 14. ALL WORK TO BE DONE PER APPROVED PLANS BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. SEE CP-2024-005800 FOR ASSOCIATED BUILDING PERMIT.
Other permits at this address
5 other permits at 2201 E TIOGA ST. Electrical, plumbing, and HVAC on the same property usually share a general contractor.
New Construction or Additions - NEW CONSTRUCTION OF 4 STORY 51 DWELLING APARTMENT BUILDING WITH AMENITY SPACES FOR RESIDENTS. INTERIOR INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR LISTE...
New Construction - Provide new incoming service for residential units (1600 amp) and 1000 amp for the rest of the building. Install all branch circuits for power and lighting. Install tel/CATV and low...
New Construction or Additions - INSTALL SANITARY AND STORM CTs, FAIs, MDs & 2" WDP CURB TO BUILDING.
Excavation - FOR THE EARTHWORK EXCAVATION AND SITE IMPROVEMENTS TO INCLUDE SITE DEMOLITION, GRADING, UNDERGROUND STORM AND SANITARY UTILITY INSTALLATION INCLUDING STORMWATER MANAGEMENT SYSTEM, RAIN GA...
Tank Install/Removal - **TANK REMOVAL PERMIT** FOR THE REMOVAL OF ONE (1) 13,500 GALLON UNDERGROUND OIL STORAGE TANK (UST). REMOVE ANY PRODUCT/WATER FROM TANK, CLEAN TANK, CONDUCT A CONFIRMATORY SOIL...
More New Construction permits in Philadelphia
New construction, addition, GFA change - FOR THE PARTIAL DEMOLITION OF AN ATTACHED BUILDING. SIZE AND LOCATION AS SHOWN IN APPLICATION/PLANS
New construction, addition, GFA change - FOR THE ERECTION OF A PERGOLA OVER AN EXISTING ROOF DECK ON AN EXISTING ATTACHED STRUCTURE. SIZE AND LOCATION AS SHOWN IN PLANS.
New construction, addition, GFA change - FOR THE ERECTION OF AN ATTACHED NEW STRUCTURE WITH A CELLAR AND AN ACCESSORY ROOF DECK (FOR RESIDENTIAL USE ONLY) WITH ROOF ACCESS STRUCTURE. SIZE AND LOCATION...
New construction, addition, GFA change - FOR THE ERECTION OF AN ATTACHED NEW STRUCTURE WITH A CELLAR AND AN ACCESSORY ROOF DECK (FOR RESIDENTIAL USE ONLY) WITH ROOF ACCESS STRUCTURE. SIZE AND LOCATION...
New Construction - FOR THE INSTALLATION OF A 2-INCH FIRE SERVICE LINE FOR AN AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM WITH A 2 INCH WILKINS 950XLT2BFSS BACKFLOW PREVENTION ASSEMBLY IN ACCORDANCE WI...